04_21 Measuring IOP Using Other Tonometry Methods
Session information
- Title:
- 04_21 Measuring IOP Using Other Tonometry Methods
- Description:
- This session seeks to demonstrate the principles for measurement of IOP using tonometry methods other than Goldmann’s applanation tonometry. It offers an overview of commonly used tonometers in clinical practice, the potential of error with each type, and how these errors can be reduced.
- Hierarchy:
- Ophthalmology (Eye-Site) > Eye-Site 00 Ophthalmology Curriculum > What the Ophthalmologist is able to do (Technical Intelligences) > 1) Clinical Assessment (CA) > CA8 IOP measurement > 04_21 Measuring IOP Using Other Tonometry Methods
- Author(s):
-
Wai Siene Ng
- Created:
- 15 Jun 2011
- Last Major Update:
- 24 Oct 2014
- Keywords:
- 130_072, Non-Goldmann tonometry, tonometry, Mackay-Marg tonometry, Non-contact tonometry, Rebound tonometry, Ocular Response Analyzer, Icare tonometer, Indentation, Pressure of air, Cornea, Pneumatonometer, Tonopen, Tonopen, Difference, intraocular pressure, atmospheric pressure, Goldmann applanation tonometer, Perkins tonometer, IOP, disinfection, hysteresis, corneal effects on IOP, IOP in children, clinical examination, optometry
Share this item
- Copy URL
Overall rating
4/5
4/5
Content
4/5
4/5
Presentation
4.4/5
4.4/5
Interactivity
4.3/5
4.3/5
Self assessments
4.1/5
4.1/5
Overall rating
4/5
4/5
Content
4/5
4/5
Presentation
4.4/5
4.4/5
Interactivity
4.3/5
4.3/5
Self assessments
4.1/5
4.1/5
- Title:
- 04_21 Measuring IOP Using Other Tonometry Methods
- Description:
- This session seeks to demonstrate the principles for measurement of IOP using tonometry methods other than Goldmann’s applanation tonometry. It offers an overview of commonly used tonometers in clinical practice, the potential of error with each type, and how these errors can be reduced.
- Hierarchy:
- Ophthalmology (Eye-Site) > Eye-Site 00 Ophthalmology Curriculum > What the Ophthalmologist is able to do (Technical Intelligences) > 1) Clinical Assessment (CA) > CA8 IOP measurement > 04_21 Measuring IOP Using Other Tonometry Methods
- Author(s):
-
Wai Siene Ng
- Created:
- 15 Jun 2011
- Last Major Update:
- 24 Oct 2014
- Keywords:
- 130_072, Non-Goldmann tonometry, tonometry, Mackay-Marg tonometry, Non-contact tonometry, Rebound tonometry, Ocular Response Analyzer, Icare tonometer, Indentation, Pressure of air, Cornea, Pneumatonometer, Tonopen, Tonopen, Difference, intraocular pressure, atmospheric pressure, Goldmann applanation tonometer, Perkins tonometer, IOP, disinfection, hysteresis, corneal effects on IOP, IOP in children, clinical examination, optometry